Good ventilation design in Ireland starts in the house, not in a catalogue. Before we install MVHR, MEV or a single room heat recovery unit in an existing home or a renovation, one of our team surveys it, because what decides whether a system works does not show up in photos: which way the joists run, where the unit can sit, where the old fans really vent to, and how airtight the house will be once the builders leave. The survey turns those answers into a design, and the design becomes the quote. Our ventilation installation service fits all three; this is what we check first.
Key takeaways
- We survey before we give a final price. The preliminary quote by email from your photos is free; the survey is a paid visit.
- The rooms and wet rooms set the size of the system; the duct routes decide which system it is.
- The unit needs a place you can reach, power and, for MVHR, a condensate drain.
- We design for the house as it will be after the works, which is usually tighter.
- Talk to us before the ceilings are closed: a duct planned then costs far less than one added after the plasterer.
Why does a renovation need a survey before the final quote?
Because an existing house hides the answers. In a new build the ventilation is drawn onto the plans before anything is built, and our guide to planning ventilation in a new build covers that case. In a house already standing, the design has to fit the routes and structure that are there. Photos or floor plans give us enough for a price range. The survey confirms the routes and positions in the house itself, which is why it is a paid visit: it is design work done on site. It is also where we check the design against Part F of the Building Regulations, explained in Technical Guidance Document F, which sets the ventilation requirements for homes in Ireland.
What do we check on the survey?
Eight things, and any one of them can change the system we recommend.
The rooms and the wet rooms
We confirm the floor area, count the bedrooms and living rooms, and list every wet room: kitchen, bathrooms, en suites, utility, downstairs toilet. Moist air is taken out of the wet rooms; in whole house MVHR fresh air is supplied to the bedrooms and living rooms. Those numbers set the airflow room by room and the size of the unit. Our post on the airflow rates MVHR systems need to meet explains how the rates are worked out.
Where the ducts can run
This most often decides between systems. In the loft we look at the space above each ceiling and the way down to the rooms below. Inside, we check which way the joists run: a duct runs easily along a joist space and with difficulty across it, and holes in joists are limited by what the structure allows. Where there is no clear route we look for places to box in: a room corner, the back of a wardrobe, a bulkhead on the landing. We want routes without sharp bends or long cold stretches, and insulated duct wherever it crosses a cold loft.
Where the unit can sit
A whole house unit needs a dry space and, above all, access: the attic, a utility room, a hot press with space to spare or a room over the garage. We check the hatch, the ladder and a safe path to it, because MVHR filters need changing and the system needs its annual service. A unit nobody can reach is one of the classic problems a survey prevents, along with a fan too weak for its room and a duct that ends in the loft.
Where the air goes in and out
MVHR needs a fresh air intake and an exhaust on an outside wall or the roof, apart from each other and away from a boiler flue. Single room units need a position on each room’s outside wall, so we check what the wall is made of before anything is drilled and how the grille will look outside. In an apartment the management company may need to approve the opening.
The fans and vents you already have
We run every existing fan and follow its duct to where it ends. A fan venting into the roof space is common; our job story on a fan venting into the loft in Malahide shows what that does. We note the wall vents and trickle vents too. With MEV ventilation the vents become the fresh air inlets, so they stay or are upgraded. With whole house MVHR the old fans come out and unused vents are usually sealed to keep the system balanced.
How airtight the house will be after the works
New windows, wall insulation, a sealed chimney and new attic insulation close the gaps that used to air an older house without anyone noticing. A house that was draughty in September can be tight by Christmas, and the moisture from showers, cooking and drying clothes then has nowhere to go. The tighter it will be, the more sense whole house MVHR makes. If your renovation goes through an SEAI One Stop Shop, ventilation belongs in that plan, and we work with SEAI-registered One Stop Shop providers on whole-house retrofit projects.
Power, condensate and controls
A central unit needs a power supply beside it, single room units need power at each wall, and a bathroom boost switch needs a cable route. An MVHR unit also needs a condensate drain with a fall to a waste pipe, protected from frost in a cold loft. We plan all of this with your builder up front rather than adding it afterwards.
What you expect to hear
We ask about noise early, including who sleeps next to the loft hatch or the hot press, because most noise in a ventilation system comes from the design: a duct too small for its air, flexible duct crushed behind plasterboard, a unit fixed to a light partition beside a bedroom. Planning for noise is easy on the survey and hard once the ceilings are closed.
Two jobs from our team
On a recent survey in Dublin, one of our team was on site with the builder, checking a timber frame opening and looking at where the ducting could run and where the unit could sit. As our post about it says, it is not the glamorous part of ventilation, but it is the part that decides if a system works. If you are building, extending or renovating, talk to us early, before the walls are closed.
In Arklow, Co. Wicklow, the problem was one we see in bedrooms all the time: two people sleeping in a closed room release a lot of moisture overnight, and with the window shut it lands on the glass and the coldest wall. The homeowner wanted fresh air without ducting the whole house, so we supplied and fitted decentralised heat recovery units. We core drilled through the external wall, fitted the units with an inline section in the loft, and added sockets in two bedrooms to power them. The result: steady fresh air in the bedrooms, much of the heat kept inside, less condensation on windows and walls, and no need to sleep with the window open in winter. Our single room heat recovery page explains when room units are a better fit than a fully ducted system.
How does the survey become a design and a quote?
- Preliminary quote. You send photos or floor plans with your Eircode; we email a free preliminary quote with the system we expect to recommend and a price range.
- Survey. We check the eight points above and agree positions with you and your builder.
- Design. We size the system and place the unit, the duct routes, the valve or unit in each room and the outside terminals, with power, drainage and boxing in noted.
- Quote. A written quote for that design: what is fitted, where, and for how much.
- Installation and commissioning. We fit the system, then set and check the airflow so it does what it was designed to do. For MVHR you get the measured figures at handover.
Whole house MVHR installed in 2026 costs €5,500 to €6,000 for a home up to 100 square metres, €6,000 to €7,000 for 100 to 200 square metres, €7,000 to €8,000 for 200 to 300 square metres and €8,000 to €9,500 above that. The rooms and the duct routes decide where a renovation lands; our MVHR installation page sets out what the price includes. Single room units and MEV are quoted after we have seen the house. We provide a 5 year warranty on MVHR units, provided that the system is serviced annually by VentSolve throughout the warranty period, which is one more reason the survey makes sure the unit can be reached. We hold NZEB Ventilation Certification.
Frequently asked questions
Is the ventilation survey free?
No. The preliminary quote by email is free: send us photos or floor plans with your Eircode and we reply with the system we expect to recommend and a price range. The site survey is a paid visit, because that is where the design is done and the routes, positions and power are confirmed.
When should the survey happen in a renovation?
Before first fix, while the floors are up and the ceilings are open, so a duct can run through the joists and disappear. The second best time is before the plasterer. After that a good design is still possible, but it leans towards single room units or boxing in.
Can MVHR be fitted in an existing house?
Often, yes. It needs a place for the unit with access for filter changes and a duct route to every room, usually through the loft and joist spaces with some boxing in. Where those routes do not exist, single room heat recovery units or MEV are the honest alternatives, and the survey shows which fits.
Does a renovation have to meet Part F?
Part F of the Building Regulations, with Technical Guidance Document F, sets the ventilation requirements for homes. What applies depends on the works: an extension is not the same as replacing a bathroom fan. Your architect or designer will confirm what applies, and we design the ventilation to those requirements.
What happens to my old extractor fans?
With whole house MVHR the extract valves take over from the bathroom and kitchen fans, so the fans come out. With MEV the central unit does the extracting, so they come out too. With single room units, a fan that works and vents outside can stay; one that vents into the loft gets fixed.
Planning a renovation? Send us photos of the rooms, the loft and your existing fans, or your floor plans, with your Eircode through the form below, and we will email a free preliminary quote within 24 hours. If you would rather talk it through, call us on (01) 685 6363. We work across Dublin and Leinster.